XPOMATPOH HPLC
High performance liquid chromatograph is an indispensable qualitative and quantitative tool in modern laboratory. The xpomatpoh HPLC high performance liquid chromatograph adopts a building block desigen
Key words:
Gear tooth shaft, worm gear
Classification:
Product Description
Product | Isocratic pump | Binary high pressure gradient pump | Quaternary low pressure gradient pump |
Pump type | tandem double plunger type | tandem double plunger type | tandem double plunger type |
gradient valve | 4 channels separated gradient valve, each channel could be replaced or monitored separately | ||
Online Degassing | Optional Single channel degasser | Optional 2 Channels degasser | Standard 4 Channels degasser |
Max.Pressure | 62MPa | 62MPa | 62MPa |
Pressure Pulsation | ≤1%(@Flow rate≤5mL/min,Pressure≤4000psi) | ||
Flow Rate Range | 0.001-10.000mL/min | 0.001-10.000mL/min | 0.001-10.000mL/min |
Flow Rate Accuracy | ±0.5%(@1.000 mL/min,water) | ±0.5%(@1.000 mL/min,water) | ±0.5%(@1.000 mL/min,water) |
Flow Rate Precision | RSD≤0.06%(@1.000 mL/min,water) | RSD≤0.06%(@1.000 mL/min,water) | RSD≤0.06%(@1.000 mL/min,water) |
Pressure Pulsation | ≤1%(@flow rate≤5mL/min,pressure≤4000psi) | ≤1%(@Flow rate≤5mL/min,Pressure≤4000psi) | |
Gradient Accuracy | ±0.5% | ±1% | |
Gradient Repeatability | ≤0.2%SD | ≤0.2%SD | |
Online Wash | Standard ,Piston and seals protection | Standard ,Piston and seals protection | Standard ,Piston and seals protection |
solvent shifting valve | 2 channel solvent shifting valve which support 2 different solvents | 4 channel solvent shifting valve which support 4 different solvents | |
Size | 500mm × 386mm × 170mm | 500mm × 386mm × 254mm | 500mm × 386mm × 254mm |
Product | Auto sampler | Manual injector |
Volume of Sample loop | 2 set of standard 54 vails position racks, optional 96 & 384 wellplate | |
Loop volume | Standard 100μL(Optional 10μL、20μL、50μL) | Standard 20μL(Optional 10μL、50μL、100μL) |
Sampling Repeatability | standard:RSD≤0.5%;μL pick up:RSD≤1.0% | |
Linear | ≥0.999 | |
Sampling time | (Support preload sample injection)could reduce to 5s | |
Cross Contamination | <0.003%(Caffeine) | |
Max pressure | 42MPa(optional 103MPa) | 48MPa |
Operating temperature | 4-80℃ | 4-80℃ |
Cooling function | Optional:4-40℃ Sample temperature control and dehumidification function | |
Needle washing degassing modular | Optional | |
Size | 500mm × 386mm × 250mm |
Column oven | |
Temp. control mode | Semiconductor temperature control, double fan air circulation |
Temp. Range | Ambient+5℃-85℃;Lower than ambient 10℃-85℃ |
Temp Accuracy | ±1℃ |
Temp control precision | ±0.1℃ |
Size | 500mm × 386mm × 165mm |
UV-VIS Detector | |
Wavelength | 190-900nm;(Grate:Horiba;Silicon Photocell:Hamamatsu) |
Light Source | Deuterium lamp (Hamamatsu) & Tungsten lamp |
Spectral Width | 8nm |
Wavelength Accuracy | ±1nm |
Wavelength Precision | ±0.1nm |
Noise | ±0.25×10-5AU(ASTM) |
Drift | 1×10-4AU/h |
Linear Range | >2.5AU |
Max.Sampling Rate | 100Hz |
Flow cell light path | 10mm |
Flow cell volume | 12μL |
Size | 500mm × 386mm × 165mm |
Wavelength calibration | Correction wavelength of built-in mercury lamp |
Maintenance | Replace deuterium lamp, tungsten lamp and flow cell in front |
Diode Array Detector | |
Wavelength | 190-800nm |
Light Source | Deuterium lamp (Hamamatsu) & Tungsten lamp |
Diode Array | 1024 |
Spectral Width | 1、2、4、8nm |
Wavelength Accuracy | ±1nm |
Wavelength Precision | ±0.1nm |
Noise | ≤1.2×10-5(ASTM,Wavelength:254nm,Bandwidth: 4 nm,Slit width: 4 nm,Sampling rate:1Hz) |
Drift | 0.5×10-3AU/h |
Linear Range | >2.0AU |
Max.Sampling Rate | 100Hz |
Flow cell light path | 10mm |
Flow cell volume | 12μL |
Channel | 12 |
Wavelength calibration | Built in holmium glass correction wavelength |
Maintenance | Replace deuterium lamp, tungsten lamp and flow cell in front |
FLD | |
Light source | Xenon lamp |
Wavelength | 200-650nm |
Spectral Width | 20nm |
Wavelength Accuracy | ±2nm |
Wavelength repeatability | ±0.2nm |
S/N | The signal-to-noise ratio of Raman peak of water is greater than 1200(Ex=350nm,answer time1.5sec) |
Flow cell volume | 12μL |
Flow cell pressure | 2MPa |
Flow cell material | SUS 316L , PTFE , quartz |
Delay volume before flow cell | 15μL |
Delay volume after flow cell | 16μL |
Multiple wavelength | 200-650nm (wavelength range) and supports 2-wavelength simultaneous scanning mode of 0.5sec/per wavelength |
Sensitivity: 3 grades setting | HIGH, MED, LOW(×1,×32,×1024) |
Gain | 3 grades setting:×1,×4,×16 |
Answer | Time constant: 11grades can be set (no filtering, 0.05, 0.1, 0.5, 2, 3, 6, 8, 10) |
Spectrum scan | Support pump stop scanning, save background data and output data deducting background |
Scanning speed | 24,120,600,3000nm/min (Step 1nm) |
Output | two modes are optional: analog output and digital signal output (10mV); Ch1 and CH2 are optional (only in dual wavelength mode); Output range can be set (only under digital output) |
Light source working time monitoring function | it can record up to 9999.9 hours |
Size | 420mm×260mm×210mm |
Weight | 16kg |
Temperature | 4-35℃ |
Working environment humidity | 20-85% (non condensing) |
Power | AC 220-240V 400VA 50/60Hz |
RID | |
Analysis method | Refraction method |
Reflective range | 1.00~1.75 |
Linear | 600μRIU |
Output | 0.25-512μRIU |
Noise | ≤2.5nRIU(Pure water, answer1.5s) |
Drift | 0.2μRIU/h |
Answer | 0.1,0.25,0.5,1,1.5,2,3,6sec |
Auto zeroing adjustment | fully automatic zeroing (Optics + calculation) |
Offset range | 0-10 μ RIU (resolution50nriu) |
Auto zero | Full range |
Integrator output | 0-1V/FS(sensitivity2mV/μRIU,8mV/μRIU) |
Recorder output | 0-10mV |
Other output | (1) Preparation (2) Solution leakage (3) Error (overheating zero glass center position optical balance error parameter loss low energy intensity) (contact capacityDC24V 0.1amax) |
Temperature contro | loff, 30-50 ℃ (increasing range 1 ℃) Thermal resistance wire 77 ℃ |
Communication | USB |
Flow cell | 2 chamber |
Flow cell volume | 8μL |
Speed | Standard0.2 ~ 3.0mL/minMax10mL/min(with water) |
Max pressure | 50kPa |
Dead volume | IN-Cell60μL Cell-OUT600μL |
Power | AC 100V-240V±10%,50Hz/60Hz,150VA max |
Size | 400mm×260mm×150mm |
Weight | 12Kg |
ELSD | |
Temperature | Ambient to 130℃ |
Step | 1℃ |
Temp control accuracy | ±1℃ |
Gas | Nitrogen or air |
Gas input pressure | 2bar-5bar |
Gas pressure testing precision | 0.01bar |
Gas flow rate | 1L/min -4L/min |
Gas flow rate accuracy | ≤1% 或 0.02L/min |
Liquid flow rate | 10μL/min-3mL/min |
Light source | 650nm semiconductor laser |
Detection element | photomultiplier tube |
Baseline noise | <0.05 mV(1.0 mL/min 100% Methanol, evaporation temperature 35 ℃, gas flow 3.0 L / min) |
Drift | <1.0 mV/30 min(1.0 mL/min 100% Methanol, evaporation temperature 35 ℃, gas flow 3.0 L / min) |
Minimum detection limit | < 5.0 × Cholesterol solution in 10-6 g / ml methanol (1.0 ml / min methanol, evaporation temperature 35 ℃, gas flow 3.0 L / min) |
Typical quantitative range | 0.1μg-30μg |
Quantitative repeatability RSD | ≤3.0% |
Signal output | 0-1 V DC |
PC interface | RS232 |
Power | 220V,50Hz |
Size(LWH) | 460mm×330mm×220mm |
Working condition | Ambient 15-40℃ Humidity<90% |
Workstation | |
The workstation adopts database to save chromatographic data, and has the function of complete backup and restore of database, which is safe and reliable. | |
With multi-level user authority management and audit tracking function, it meets the requirements of FDA 21 CFR Part 11 / GMP / GLP and other regulations. | |
It has powerful data processing function, provides 25 integral events and 3 quantitative calculation methods, and supports the calculation of noise and drift; The sample content is calculated automatically by establishing the calibration curve. | |
The workstation has friendly interface, simple layout of each functional area and convenient operation; Built in standard method, which can be retrieved and used directly. | |
Report editing is convenient, with built-in multiple templates, and supports flexible editing and saving of new templates. Click to output customized reports. |
Related Products